The short answer
- Drum turns, air moves, no heat — the heater circuit is open: thermal fuse, thermostat, element, or the igniter/valve on a gas machine.
- Check the vent first. Restricted airflow is what blows thermal fuses and overheats machines.
- Test in order: thermal fuse, hi-limit thermostat, cycling thermostat, element (or igniter and coils), then the control relay.
- Do not just replace the fuse. It is a symptom of the airflow problem that opened it.
The heater circuit in one picture
An electric dryer heats with a resistance element and protects itself with two thermostats and a one-shot thermal fuse in series. Power runs through that chain, so a break anywhere in it produces exactly the same symptom: the drum turns, the air moves, and the air is cold.
| Component | Job | Failure behaviour | Test |
|---|---|---|---|
| Thermal fuse | One-shot cut-out at a set temperature | Open circuit, never resets | Continuity, unplugged |
| Hi-limit thermostat | Opens at the heater outlet if it gets too hot | Usually self-resetting; can fail open | Continuity, cold |
| Cycling thermostat | Cycles the element to hold temperature | Stuck open = no heat; stuck closed = overheating | Continuity, cold |
| Heating element | Produces the heat | Coil breaks; terminal burns | Continuity and visual check |
| Control relay / board | Switches the element | Contacts welded or open | Voltage at element during a heat call |
| Gas igniter and valve coils | Light and control the flame | Glows without flame, or no glow | Qualified technician |
Before any of that: the vent
A dryer running with a blocked vent cannot move heat out of the drum, so the heater box overheats and the thermal fuse opens. That is why the same fuse blows twice on machines whose ducts were never cleaned. Clear:
- The lint filter — every load, and wash it occasionally if it is a mesh type.
- The filter housing — vacuum it; lint passes the filter and packs the duct behind it.
- The flexible duct behind the machine — take it off and look through it. A crushed or corrugated hose full of lint is the most common single cause.
- The outside flap — check it opens when the dryer runs, and that the run is clear.
The test order
- Thermal fuse. Usually on the blower housing or heater box. Test continuity. Open = blown. Note that some fuses are not resettable and must be replaced.
- Hi-limit thermostat. Test continuity when cold. If it is open when cold, replace it.
- Cycling thermostat. Same test. A thermostat that reads open at room temperature is faulty.
- Element. Disconnect and test across the terminals. No continuity = broken element; look for a burnt wire or terminal too, because a loose terminal mimics a failed element.
- Supply to the element. If everything above tests good, check for voltage at the element during a heat call. No voltage means the relay or board is not switching.
- Gas models. Watch through the sight glass: a glowing igniter with no flame points to the valve coils; no glow points to the igniter or its circuit. Either way, this is technician work.
Narrowing it from the symptom
| What you notice | Most likely |
|---|---|
| No heat at all, drum and fan fine | Thermal fuse or open element |
| Heat for a few minutes, then cold | Hi-limit thermostat opening on a restricted vent |
| Heat on one programme only | Cycling thermostat or control logic |
| Burning smell, then no heat | Overheated terminal or failed element — stop using it |
| Gas dryer clicks, no flame | Igniter or valve coils |
| Clothes take two cycles but warm | Airflow, not the heater — see the long-dry guide |
Repair or replace
A thermal fuse, thermostat or igniter is cheap. An element is moderate and worth replacing on a dryer under about ten years old. A control board is where the arithmetic changes, and a heat-pump dryer's sealed circuit is usually beyond economic repair. Repair or replace sets out the comparison; Samsung dryer codes covers the machine that shows HE or tE instead of failing silently.
Frequently asked questions
Why did the thermal fuse blow in the first place?
Heat could not escape. The near-universal cause is a restricted lint path — a matted filter, a packed housing, a crushed duct or a blocked outside flap. Clear the whole path before fitting a new fuse.
Can a dryer heat but still not dry clothes?
Yes — that is an airflow problem, not a heater problem. The air is warm but cannot carry moisture out of the drum, so the load stays damp while the machine runs a long cycle.
Is it worth repairing a dryer that has blown two fuses?
Only after the vent has been cleaned properly, including the duct inside the wall. Two fuses in a short period means the cause was never fixed.
Sources
- Manufacturer support documentation for no-heat dryer faults and vent maintenance: Samsung, LG, Whirlpool and Bosch consumer support sections, accessed 16 November 2026.
- Service documentation on the heater circuit, thermal cut-outs and airflow detection in vented dryers.
- Editorial review against the parts trade: thermal fuse and element failure patterns across brands.
General information only. Heater design differs between electric, gas, condenser and heat-pump dryers. Unplug before any test, and leave gas work and mains wiring to a qualified technician.