Appliance Error Code Guide Codes, causes & fix order
Air conditioners · LG

LG Air Conditioner Error Codes: CH01 to CH67

LG's air conditioner codes are grouped by system rather than listed one by one, and knowing the group is most of the diagnosis: sensors, compressor, drainage, communication or fan. That decides whether it is a five-minute reset or a service call.

Checked against LG support documentation Updated 17 November 2026 8 min read

The short answer

  • CH01, CH02, CH06, CH12, CH41–CH48 — sensor faults.
  • CH21, CH23, CH26, CH29 — outdoor compressor or its control board.
  • CH04 / FL — drainage. CH05 / CH53 — communication.
  • CH10 / E6 — indoor fan. CH67 / EF — outdoor fan.
  • Reset first: off at the breaker, five minutes, back on. Many codes do not return.

The groups

GroupCodesSystemDIY?
SensorsCH01, CH02, CH06, CH12, CH41–CH48, E1, E2, E3, E7, E8, F2, F3Temperature and pipe sensors, or the main board reading themNo — reset, then service
CompressorCH21, CH23, CH26, CH29, E9Outdoor compressor, drive or protection circuitNo
DrainageCH04, FLCondensate not leaving the indoor unit, or tank fullPossibly — check the drain
CommunicationCH05, E0, CH53Indoor to outdoor signalReset, then service
Indoor fanCH10, E6Indoor fan motor or its feedbackClean the filter and check for obstruction
Outdoor fanCH67, EFOutdoor fan motor, debris or snowRemove visible debris, then service

Some models show the same fault as E or F codes instead of CH codes, especially older units. The grouping still holds.

Reset before anything else

  1. Switch off at the breaker or unplug the unit.
  2. Wait five minutes. This lets the outdoor unit's protection circuits clear.
  3. Restore power and start the unit in cooling.
  4. Watch for the code. If it returns within seconds, it is a hard fault. If it runs normally for hours and then faults, it is heat or load related and needs a different conversation.

LG's own guidance for most of these codes begins with exactly this power cycle, because an unstable supply produces many of them.

CH04: the drainage group

On a cassette or ducted indoor unit, condensation is pumped or gravity-fed away. A blocked drain line, a dirty pan or a failed pump lifts the float and stops the unit to protect the ceiling. Look for water stains around the indoor unit and check whether the drain outlet drips during operation.

On a window or portable unit, CH04 or FL can appear in very humid weather because condensate is designed to evaporate from the base. It clears as the unit runs. If it appears on dry days too, the unit needs inspection.

CH10 and CH67: fans

The indoor fan code usually follows a blocked filter or an obstruction in the blower. Clean the filters, check that the louvre and blower move freely, and reset. The outdoor fan code is often leaves, snow or a nest around the blades; clear it with the power off and see whether the code returns.

Power off at the breaker before touching an outdoor fan, and never open the electrical box. The outdoor unit's capacitor can hold a dangerous charge after the supply is cut, and refrigerant lines are under pressure. Debris removal is the limit of safe homeowner work.

What to tell the technician

  • The exact code, and whether it appears on the indoor display or by blinking lights.
  • Whether the indoor fan runs, and whether the outdoor fan and compressor run.
  • Whether it faults immediately, after minutes, or only in hot weather.
  • The model number of the indoor and outdoor units.
  • Any recent installation, move, or electrical work in the building.

That list turns a diagnostic visit into a repair visit, which is usually the difference between two callouts and one.

Repair or replace

Sensor and communication faults are modest repairs. Compressor faults on a system more than eight to ten years old usually mean comparing a new outdoor unit against the repair; the honest comparison is in repair or replace, and it applies to air conditioners as much as to washers.

Frequently asked questions

The unit works but ices up on the indoor coil — no code?

Usually airflow or refrigerant charge: a dirty filter, a blocked coil or a slow leak. It will eventually set a sensor or freeze-protection code.

Why does the code appear only in the afternoon?

High outdoor temperature raises compressor load and pressure. A marginal compressor or a dirty outdoor coil faults when the ambient is highest.

Does a CH code mean I need a new gas charge?

Not usually. Codes name electrical and sensor faults. Low refrigerant is a pressure diagnosis, not a code.

Sources

  1. LG support — "Air conditioner guide to error codes", including CH04/FL, CH05/E0/CH53, CH10/E6 and CH67/EF, accessed 17 November 2026.
  2. LG support article grouping CH01, CH02, CH06, CH12, CH41–CH48 and the E/F sensor codes, and the CH21–CH29 compressor codes.
  3. Editorial review against the service trade: drain and communication faults after installation and seasonal debris.

General information only. Codes differ by model year and market. Refrigerant and electrical work must be performed by a qualified technician.